Automatic Charger Pb 1250 SMT 3B

Device with humidity-proof electronic system - Article-No. 13125

 Boot

Pb 1250 SMT 3B 3119

Charging Programs:

1  2  4  Li

Technical Features:

BR  DC  FB  Kap  PL

SR  TK  VF  LV  Tropfen

Charging Options:

Batterien 2S

1 to Supply Batteries or
1 to 2 Starter Batteries or
1 Supply and 1 Starter Battery

Description

  • Charging programs No. 1, 2, 4 and Li (gel, AGM, acid and LiFePO4) adjustable to the battery type
  • The charging voltage is free from peaks and is controlled in such a way, that overcharging of the batteries is excluded
  • Fully Automatic Continuous Operation: The charger may be connected continuously to the battery, thus keeping the full charge. Battery discharge in case of power failure is avoided (separation by safety relay)
  • Lithium LiFePO4 Auto Wake Up: Periodical automatic activation of the battery cell balancing BMS
  • Battery regeneration in case of extended standstill periods: twice a week to avoid harmful acid accumulation
  • Parallel and Floating Operation: In case of simultaneous consumption, the battery will either continue to be charged or maintained via trickle charging. Calculation and control of the adaptation of the charging times is effected automatically by the charger
  • Unattended Charging: Multiple protection against overload, overheating, overvoltage, short circuit, reverse battery, incorrect behaviour and back discharge of the battery by electronically controlled gradual reduction down to complete separation of charger and battery by integrated safety relays
  • Connection for Battery Temperature Sensor (Accessory Temperature Sensor 825, Order No. 2001): Lead batteries (acid, gel, AGM): In case of low outside temperatures, full charging of the weak battery is improved by automatic adaptation of the charging voltage to the battery temperature, and in case of summery temperatures unnecessary battery gassing and battery load will be avoided.
    For LiFePO4 batteries, the battery temperature sensor is required: It serves for battery protection in case of high temperatures or particularly in case of low temperatures below 0 °C
  • Silent Run Function: Noise‐optimised operation (night operation) at the touch of a button
  • Power Pack Function: Allows supplyof the consumers without battery (such as during battery replacement)
  • Charging Cable Compensation: Automatic compensation of voltage losses on the charging cables
  • Integrated On‐board Mains Suppression Filter: Unproblematic parallel operation with solar systems, wind and petroldriven generators, dynamos etc. on one battery
  • Charging aid for totally discharged lead batteries: Gentle preliminary charging of the (lead‐acid, gel, AGM) battery to 8 V, followed by powerful support of the battery, in case of possibly switched‐on consumers
  • Separation of the batteries in case of power failure, overheating, incorrect behaviour (safety relay for each charging port)
  • Separate auxiliary charging port "S" for support charging and conservation of charge of the vehicle's starter battery
  • Integrated charging current distributor with 2 main charging ports, each with max. current and output capacity for short charging times
  • Charging current distributor can be switched to an own charging program for the starter battery
  • If required, the starter battery can also be charded with full charging current (short stop period of the vehicle)
  • 4 Battery capacitiy rates can be adjusted (12 charging programs in total)
  • Inputs for sensor (sense) lines, which can be optionally used in case of charging cables in overlength and/or in case of external diode charging current distributor with volage loss
  • The mains/charging capacity can be reduced in case of low capacity or restricted power supply, such as in case of weakly protected country current supply, generator operation etc. (power limint function)

Technical Details

 Supply Voltage (Mains Frequency 45 - 65 Hz) AC 110 V - 230 V
 Voltage Range Mains Function 85 V - 270 V,   short-time 305 V (5 sec.)
 Mains Voltage Range for Full Charging Capacity 190 V - 270 V
 Mains Power Consumption max. 840 W
  Mains Current Draw (AC) max. 5.2 A
 Active Sinusoidal Power Factor Correction (CosPhi < = 1) yes
 Approx. Charging Current at 110 V Supply Voltage 33 A
 Switch "AC Power Limit", Limitation of the Mains Current Draw / Capacity:
 Position "Max" (Maximum Charging Capacity): 5.2 A / 840 W
 Position "Med" (Reduced Mains and Charging Capacity): 1.9 A / 390 W
 Position "Low" (Reduced Mains and Charging Capacity): 1.4 A / 280 W
 Charging Ports Batteries "A" and "B":
 Nominal Battery Voltage Lead/LiFePO4 Battery 12 V / 12 V-13.3 V
 Battery Capacity adjustable (A or A+B total) 88 Ah-550 Ah
 Charging Current Phase I (A, B or A+B) max. 50 A
 Charging/Floating/Load Current, controlled, Phase U1, U2, U3 0 A - 50 A
 Automatic Charging Current Distributor Batteries A/B yes
 Minimum Battery Voltage for Charging Start 0 V
 Preliminary Charging Current, Deeply Discharged Batt. 0 V-8 V 25 A
 Reverse Current from Battery (Power Failure) < 0.2 mA
 Reset Voltage (30 sec.), depending on Battery Type 12.75 V / 13.25 V
 Limit of Charging Voltage (Protection of Connected Consumers) 15.0 V
 External Overvoltage Disconnection (20 sec.) 15.5 V
 Ripple Factor Voltage < 40 mV rms
 Charging Timer 4-fold
 Safety Protect. ag. Reverse Batt./Short Circuit/Back Discharge yes
 Safety Timer per Charging Phase I/U1/U2 yes
 Sensor Lines "Sense" Inputs, for Battery "-" and "+A",  "+B" yes
 Lead Battery Regeneration at extended down-time 2x week: 1 h yes
 LiFePO4-Auto Wake Up in case of extended down-time every 10 days/0.5 h yes
 or LiFePO4 Lithium Standstill Trickle Charge (Seasonal Operation yes
 Main Charging Port Battery "A" (Master):
 Selectable Charging Programs Lead-Gel/AGM/Acid, LiFePO4 4
 Charging/Floating/Load Current, controlled, Phase IU1oU2oU3 0 A - 50 A
 Input for Battery Temperature Sensor: "A" yes
 Power Pack Operation (e. g. Supply During Battery Replacement) yes
  2. Charging Port Battery "B"(Integrated Charging Current Distributor, switchable):
 4 Charging Programs, Optionally Identically with Battery "A" Master yes
 or Charging Program for Vehicle (Lead) Starter Battery yes
 Charging/Floating/Load Current, controlled, Phase IU1oU2oU3 0 A - 50 A
 Input for Battery Temperature Sensor "B" yes
 Power Pack Operation (e. g. Supply During Battery Replacement) yes
 3. Auxiliary Charging Port "C" (Signalling Port Mains)
 Nominal Battery Voltage (Lead) 12 V
 Charging Current or Rating as Signalling Port 0 A - 2 A
 Safety Protect. ag. Overcharg./Reverse Batt./Short Circuit/Back Discharge yes
 Connection for Remote Control Automatic Charger yes
 Fitting Position of Unit any
 Temperature Range -20/+45°C
 Speed-controlled, Temperature-controlled Fan yes
 Gradual Reduction of Charging Capacity at Overtemperature yes
 Safety Disconnection in Case of Overheating yes
 Noise-reduction of Fan, Night Operation (Silent Run) yes
 Protection Class/System of Protection I / IP21
 Dimensions, incl. mounting flanges (W/H/D) 160 x 72 x 305 mm
 Weight 2450 g
 Ambient Conditions, Humidity of Air max. 95 % RH, no condensation
 Safety Regulations EN 60335-2-29
 Delivery Scope: Mains supply cable with shock-proof plug, Operating Manual

Charging Programs

1 „Gel“: Charging Program for Gel Batteries, Characteristic Line IU1oU2oU3
Adapted to closed, gas-tight gel/dryfit batteries with determined electrolyte, which are generally requiring a higher charging voltage level and longer dwell times U1 to achieve short charging times with particularly high capacity storage and to avoid total discharge. Also recommended for EXIDE MAXXIMA a high-current battery in AGM filament technology.

2 „AGM“: Charging Program for AGM/Fleece Batteries, Characteristic Line IU1oU2oU3
Adapted to charging closed, gas-tight AGM (absorbed glass mat) batteries and batteries in lead-fleece technology requiring a particularly high level U1 with adapted dwell times for full charging and after that a moderate level U2 for trickle charge (round cell and plate technology).

4 „UNIVERSAL“: Charging Program for Lead, Acid/Lead-Acid Batteries: Characteristic Line IU1oU2oU3
Universal program for charging and conservation of charge of acid batteries in vehicles (mixed operation mobile/stationary). Still offers short charging times, good charging factor and good acid mixing with average level U1 for open and closed, low-maintenance, maintenance-free standard, drive, lighting, solar and heavy duty batteries.

Li „LiFePO4“: Charging Program for Lithium Batteries, Characteristic Line IU1oU2oU3
Charging program for lithium LiFePO4 batteries with completely integrated electronic system and safety circiut (BMS). Automatic trickle charging of the LiFePO4 battery when the vehicle is stopped (seasonal operation) to maintain a charging state of 50‐80 %, which is advantageous for the battery lifetime. Powers also 12 V consumer loads, such as alarm systems, WLAN etc., as well as the vehicle's starter battery.

Technical Features

BR Automatic battery regeneration   FB Connection remote control / remote indicator
DC Power pack function (battery replacement)   Kap Battery capacity (size) adjustable
LV Charging current distributor
for one or several batteries
  PL Power limit funktion
(Reduction of the mains/charging capacity)
SR Silent run funktion (reduction at night)   TK Temperature compensation
VF Voltage sensor
(in case of very long charging cables)
  Tropfen  Electronic system humidity-proof 

Downloads

Anleitung Katalog

Accessories

Fernbedienung S Ladegeraete 2075

  Betriebs Fernanzeige IP67    Batterie-Status-Anzeige 2082

Remote Indicator IP67 (Art. 2081)

Charger State Monitor IP67 (Art. 2082)

Temp Sensor 2001  

Remote Control S (Art. 12075)

Temperature Sensor 825 (Art. 2001)

 

 

Standard version:
Automatic Charger Pb 1250 SMT 3B
  (Art. 3125)

 

EMHC CIVD
Go to top