Technical Features:
|
1 Supply and 1 Starter Battery or |
Charging Capacity in [V]/[A] | 12 / 20 / 40 |
Nominal Operating Voltage (AC) in [V] | 230 |
Operating Voltage Range (AC) in [V] | 190 - 265 (Full Charging Capacity) |
Power Consumption (AC) in max. [W] | 980 |
Sinusoidal Power Factor Correction (CosPhi = 1) | yes |
Nominal Battery voltage (DC) in [V] | 12 |
Battery Capacity in [Ah]in [Ah] | 50 - 230 / 90 - 480 |
Charging Current in [A] | 20 / 40 |
Auxilary Charging Port "S" in [A] | - |
Characteristic Line of Charging | IU1oU2 |
Voltage limitation during all charging modes and programs [V] | 15 |
Ripple Factor Voltage in [mV] rms | < 50 |
Number of Charging Ports | 2 |
Mounting Position of Unit | any |
Temperature Range [°C] | -20 bis +45 |
Protection Class/System of Protection | I / IP 21 |
Dimensions (WxDxH) in [mm] - Dimensions incl. mounting flanges, without connections |
305 x 90 x 265 |
Weight in [g] | 3900 |
Mark of conformity (CE) | EN 60335-2-29 |
Ambient Conditions, Humidity of Air: max. 95 % RH, No Condensation | |
Delivery Scope: Mains supply cable, 2 Temperature Sensors, Operating Manual |
![]() |
„Gel“: Charging Program for Gel Batteries, Characteristic Line IU1oU2oU3 Adapted to closed, gas-tight gel/dryfit batteries with determined electrolyte, which are generally requiring a higher charging voltage level and longer dwell times U1 to achieve short charging times with particularly high capacity storage and to avoid total discharge. Also recommended for EXIDE MAXXIMA a high-current battery in AGM filament technology. |
![]() |
„AGM“: Charging Program for AGM/Fleece Batteries, Characteristic Line IU1oU2oU3 Adapted to charging closed, gas-tight AGM (absorbed glass mat) batteries and batteries in lead-fleece technology requiring a particularly high level U1 with adapted dwell times for full charging and after that a moderate level U2 for trickle charge (round cell and plate technology). |
![]() |
"DIN 0510“: Charging Program for Lead, Acid/Lead-Acid Batteries, Characteristic Line IU1oU2oU3 General characteristic line DIN for charging and conservation to charge of open and closed lead storage batteries with removable cell plugs and possibility of acid level control and acid level correction (maintenance). Also suitable for recently developed, closed battery types (low-antimonous, with lead-silver alloy, calcium etc.) with low and very low water consumption. Allows short charging times with high level U1, high charging factor and high acid mixing, even during stationary application (acid accumulation) of "wet" drive, lighting, solar, heavy duty and standard batteries. |
![]() |
„MOTOR“: Charging Program for Lead, Acid/Lead-Acid Batteries, Characteristic Line IU1oU2oU3 Characteristic line similar to dynamo/generator for mobile application (acid accumulation) with particularly low maintenance (battery gassing, water consumption). Charging and conservation of charge of starter batteries in intervention vehicles, according to a customary suggestion of the Standard Committee Fire Protection (FNFW). For conventional, standard starter batteries, starter batteries being "absolutely maintenance-free", "maintenance-free according to EN", "maintenance-free according to DIN", "maintenance-free", "lowmaintenance". |
Other capacity
combination