Automatic Charger VAC 1215 M 3A

Article-No. 0404

   Blaulicht  Offroad

 Boot

VAC 1215 M 3A

Charging Programs:

1  2  3  5  Li

Technical Features:

BR  DC  Equ  FB  LV

SR  TK  TS  Tropfen

Charging Options:

Batterien 2S

1 to 2 Supply Batteries or
1 to 2 Starter Batteries or
1 Supply Battery and 1 Starter Battery

Front

Description

  • Charging programs No. 1, 2, 3, 5 (gel, AGM, acid, start) and LiFePO4 adjustable to the battery type
  • Outstanding charging technology
  • The charging voltage is exempt from peaks, and it is controlled in such a way, that overcharging is excluded
  • Integrated charging current distributor with 2 main charging ports, each with max. current and output capacity
  • For mixed operation with 1 supply and 1 starter battery, a separate starter charging program can be adjusted at the built-in charging current distributor
  • If required, the starter battery can also be charged with full charging current (short stop period of the vehicle)
  • Additional auxiliary charging port "S" for support charging and trickle charge of a further starter battery (max. 2 A) or as signalling port +86 for motor locking while the vehicle is connected to mains
  • All-automatic continuous operation for permanent readiness for use of the vehicle
  • Lithium LiFePO4 Auto Wake Up: Periodical automatic activation of the battery cell balancing BMS
  • Precise battery temperature compensation, temperature sensor(s) is (are) included in the standard delivery
    For LiFePO4 batteries, the battery temperature sensor is required: It serves for battery protection in case of high temperatures or particularly in case of low temperatures below 0 °C
  • Equalization function (the characteristic line IUIU can be activated manually for compensation charging of the cells)
  • Intelligent microprocessor control observing the simultaneous supply of consumers
  • Battery regeneration in case of extended stop periods twice a week
  • Compensation of the voltage loss on the charging cables ensuring exact observation of the charging voltage rates
  • Separation of the batteries in case of power failure, overheating, incorrect behaviour (safety relay for each charging port)
  • Adjustable silent run function (reduction at night)
  • Power pack function allows continued operation of the consumers and preservation of data, such as in case of battery replacement
  • The electronic system is protected against humidity
  • Variable fitting position

Technical Details

 Charging Capacity in [V]/[A] 12 / 15
 Nominal Operating Voltage (AC) in [V] 230
 Operating Voltage Range (AC) in [V] 190 - 265 (Full Charging Capacity)
 Power Consumption (AC) in max. [W] 240
 Sinusoidal Power Factor Correction (CosPhi = 1) yes
 Nominal Battery voltage (DC) in [V] 12
 Battery Capacity in [Ah] 38 - 170
 Charging Current in [A] 15
 Auxilary Charging Port "S" in [A] 2
 Characteristic Line of Charging IU1oU2
 Voltage limitation during all charging modes and programs [V] 15
 Ripple Factor Voltage in [mV] rms < 50
 Number of Charging Ports 2 + S
 Mounting Position of Unit any
 Temperature Range [°C] -20 to +45
 Protection Class/System of Protection I / IP 21
 Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections
210 x 71 x 160
 Weight in [g] 1280
 Mark of conformity (CE) EN 60335-2-29
 Ambient Conditions, Humidity of Air:  max. 95 % RH, No Condensation
 Delivery Scope: Mains supply cable, 1 Temperature Sensor, Operating Manual

Charging Programs

1 „Gel“: Charging Program for Gel Batteries, Characteristic Line IU1oU2oU3
Adapted to closed, gas-tight gel/dryfit batteries with determined electrolyte, which are generally requiring a higher charging voltage level and longer dwell times U1 to achieve short charging times with particularly high capacity storage and to avoid total discharge. Also recommended for EXIDE MAXXIMA a high-current battery in AGM filament technology.

2 „AGM“: Charging Program for AGM/Fleece Batteries, Characteristic Line IU1oU2oU3
Adapted to charging closed, gas-tight AGM (absorbed glass mat) batteries and batteries in lead-fleece technology requiring a particularly high level U1 with adapted dwell times for full charging and after that a moderate level U2 for trickle charge (round cell and plate technology).

3 "DIN 0510“: Charging Program for Lead, Acid/Lead-Acid Batteries, Characteristic Line IU1oU2oU3
General characteristic line DIN for charging and conservation to charge of open and closed lead storage batteries with removable cell plugs and possibility of acid level control and acid level correction (maintenance). Also suitable for recently developed, closed battery types (low-antimonous, with lead-silver alloy, calcium etc.) with low and very low water consumption.
Allows short charging times with high level U1, high charging factor and high acid mixing, even during stationary application (acid accumulation) of "wet" drive, lighting, solar, heavy duty and standard batteries.

5 „MOTOR“: Charging Program for Lead, Acid/Lead-Acid Batteries, Characteristic Line IU1oU2oU3
Characteristic line similar to dynamo/generator for mobile application (acid accumulation) with particularly low maintenance (battery gassing, water consumption). Charging and conservation of charge of starter batteries in intervention vehicles, according to a customary suggestion of the Standard Committee Fire Protection (FNFW). For conventional, standard starter batteries, starter batteries being "absolutely maintenance-free", "maintenance-free according to EN", "maintenance-free according to DIN", "maintenance-free", "lowmaintenance".

Li „LiFePO4“: Charging Program for Lithium Batteries, Characteristic Line IU1oU2oU3
Charging program for lithium LiFePO4 batteries with completely integrated electronic system and safety circiut (BMS). Automatic trickle charging of the LiFePO4 battery when the vehicle is stopped (seasonal operation) to maintain a charging state of 50‐80 %, which is advantageous for the battery lifetime. Powers also 12 V consumer loads, such as alarm systems, WLAN etc., as well as the vehicle's starter battery.

Technical Features

BR Automatic battery regeneration   DC Power pack function (battery replacement)
Equ Equalization function
(compensation charging of the cells)
  FB Connection remote control / remote indicator
LV Charging current distributor
for one or several batteries
  SR Silent run funktion (reduction at night)
TK Temperature compensation   TS Temperature sensor is included
in the standard delivery
Tropfen Electronic system humidity-proof      

Downloads

Anleitung Katalog

Accessories

Fernbedienung S Ladegeraete 2075

       
Betriebs Fernanzeige IP67 Batterie-Status-Anzeige 2082

Remote Control S (Art. 2075)

Remote Indicator IP67 (Art. 2081)

Charger State Monitor IP67 (Art. 2082)

EMHC CIVD
Go to top