Peripheral devices – Circuit distributor
… for the sake of safety
- Home
- /
- Circuit distributor
PLUS-DISTRIBUTOR 6
Compact plus distributor with 6 individual circuits for the professional distribution and fusing of small to medium-sized consumers on the battery plus side. Two large collective terminals for cable cross-sections of up to 16 mm² and a current carrying capacity of max. 50 A are used for power supply and feed-through distribution. The fuse holders can be loaded up to max. 20 A, as can the 6 connection terminals for the consumers. They allow the connection of cable cross-sections up to 4 mm². The following standard FKS fuses are included in the scope of delivery: 4 x 7.5 A, 10 A, 15 A.
MINUS-DISTRIBUTOR 12
Compact negative distributor with 12 individual circuits for the professional distribution of small to medium-sized consumers on the negative side of the battery. Two large collective terminals for cable cross-sections up to 16 mm² and a current carrying capacity of max. 50 A are used for current routing and feed-through distribution. The distribution terminals on the consumer side allow the connection of cable cross-sections up to 4 mm² with a maximum current carrying capacity of 20 A. Also recommended for ground connection in the case of insulating vehicle bodies or inadequate ground conditions.
PLUS-DISTRIBUTOR 8
Like Plus Distributor 6, but with six fused outlets for larger loads. The total current load capacity is max. 96 A. The positive supply line from the battery is connected via cable lugs for max. 16 mm² cable to a strip fuse up to max. 60 A. The output is intended for powerful consumers or chargers via cable lugs for max. 16 mm² cable. For medium-sized loads or chargers, the 2-pole screw terminal (up to 6 mm² cable) can be used in conjunction with the 30 A FSK fuse supplied. Smaller loads should be protected via the four additional connection terminals for cables up to max. 4 mm² and fuse holders for standard TCS fuses up to max. 20 A (2 x 10 A and 2 x 15 A supplied).
MINUS-DISTRIBUTOR 14
Powerful distributor on the battery minus side for 12 individual, different circuits. The total current load capacity is max. 96 A. Particularly recommended for earth distribution with insulating vehicle bodies or insecure earth conditions. The negative feed line is connected to a solid screw block with cable lug for cable cross-sections up to 16 mm2 , with the second screw block being used for negative feed-through distribution. For the consumers, 4 terminals are available to accommodate max. 6 mm² cable with max. 32 A and 8 terminals to accommodate max. 4 mm² cable with max. 20 A.
CIRCUIT DISTRIBUTOR
Charging technology at the highest level
The battery is the central element of a vehicle’s electrical system. It requires the greatest attention, maintenance and care and, above all, it must be charged correctly.