Other Accessories |
|
|
|
|
Fig. |
Art.-No. | |||||||||||||||||||||||
1 | 2000 | Individual Sensor (for e. g. Tank Sensor FL, the former Tank Transmitter Set) Tank sensor, consisting of rubber dowel, screw V2A with washer and cable lug |
||||||||||||||||||||||
2 | 2001 | Temperature Sensor 825 Temperature sensor with connection cable of 3 m length, sealed for protection against environmental pollution, for all VOTRONIC units. Bore hole for bolt M8 Temperature Sensor 625 As before, but suitable for bolt M6 |
||||||||||||||||||||||
3 | 2085 | Inside Temperature Sensor Inside temperature sensor with connection cable of 3 m length with transparent cap for installation in the vehicle. (Mounting hole 7.5 mm) Suitable for VOTRONIC VPC Series and LCD-Thermometer/Clock S |
||||||||||||||||||||||
4 | 2005 2008 |
Extension Control Cable Plug-and-go extension cable of 5 m length for VOTRONIC units, such as: Battery Computer, Ammeter, Solar Display, Remote Controls for Automatic Charger and MobilPOWER Inverter etc. - Control cable 6-pin with connector Control Cable Cable 6-pin as mentioned above but without connector |
||||||||||||||||||||||
5 | 2019 | Blind S for Front Panel 85 x 47 mm Blind cover for planned panels or for installation of own components. Dimensions: 85 x 47 mm, cutout max. 70 x 35 mm |
||||||||||||||||||||||
6 | 2016 | Mounting Frame S for Display Part Inverter For external mounting of the control panel of the VOTRONIC Inverter MobilPOWER. Appearance and mechanics (identical height 85 mm) are adapted to the VOTRONIC modular system. |
||||||||||||||||||||||
7 | 2024 | Casing for LCD Displays Plastic casing, silver lacquered, for former LCD display units with silver front panels Dimensions 87 x 83 x 27 mm |
||||||||||||||||||||||
8 | 2152 | Residual current operated Circuit-Breaker RCBO 16-30 The FI/LS combination switch integrate people, fire-, and cable protection in one module for the 230 V circuit of the vehicle. The unit features a 2-pole automatic circuit-breaker and a 2-pole current-fault circuit breaker in an industrial casing with transparent door, terminal for protective conductor and equipotential bonding as well as space for a further 2-pole fault current breaker or 2 safety automatic circuit-breaker. 230 V/16 A, release current 30 mA, TÜV (MOT) / GS-certified. Dimensions 140 x 150 x 100 mm Operating Manual |
||||||||||||||||||||||
9 | 2151 | Residual current operated Circuit-Breaker RCBO 16-30 Mini Performs like 2152, however, does not have room for an additional circuit breaker, Dimensions 100 x 140 x 100 mm |
||||||||||||||||||||||
10 | 2200 | Cutoff Relay 12 V / 70 A Disconnects the starter battery from the board battery, as soon as the motor is stopped, and reconnects both batteries in parallel when the motor is restarted for charging by the dynamo. Including female connectors and manual. Dimensions incl. mounting flange, without connections 26 x 26 x 42 mm. Not suitable for vehicles according to Euro 6 standard |
||||||||||||||||||||||
11 | 2202 | Switch Relay 12 V / 60 A Back Contact Relay (bottom contact) for installation of a Battery Charger VBCS Triple at an existing Schaudt "Elektroblock (EBL)" - Including female connectors 9.5 mm and 6.3 mm and Dimensions: 33 x 29 x 41 mm incl. mounting flange, without connections |
||||||||||||||||||||||
12 | 2201 | High-Capacity Cut-off Relay 12 V / 200 A Disconnects the starter battery from the board battery, as soon as the motor is stopped, and reconnects both batteries in parallel when the motor is restarted for charging by the dynamo. Powerful execution equipped with spark extinction diode. Power Supply Connections: Threaded bolts M6; control connections: Flat connector 6.3 mm. Dimensions: 45 x 45 x 63 mm incl. mounting flange, without connections. Including female connectors |
||||||||||||||||||||||
13 | 2216 | Power Fuse Holder 5-fold with Housing for protection of large and bolt-down fuses Fully insulated fuse holder for power fuse for protection of large consumers loads or power circuits. The fuse holder can be added, and both sides are equipped with a threaded bolt M8. Delivery excluding powerfuse (fig. 15, 17). Dimensions: 116 x 95 x 40 mm | ||||||||||||||||||||||
14 | 2218 | Power Fuse Holder with Lid for bolt-down fuses Fully insulated fuse holder for power fuse for protection of large consumers loads or power circuits. The fuse holder can be added, and both sides are equipped with a threaded bolt M8. Delivery excluding Boltdown fuses (fig. 15). Dimensions: 61 x 30 x 25 mm |
||||||||||||||||||||||
15 | see Table |
Bolt-Down Fuses to be inserted in power fuse holder No. 2218 and 2216. For 12 V and 24 V installation, bore holes M5, with inspection window and colour coding. Power Strengths and Order No. see table below
|
||||||||||||||||||||||
16 | 2251 | Power Fuse Holder with Lid Completely isolated fuse holder for power fuse for protection of large consumers or power circuits. Both sides of the fuse holder are equipped with a thread M8. Delivery excluding power fuse (fig. 13). Dimensions: 122 x 42 x 39 mm |
||||||||||||||||||||||
17 | see Table |
Power Fuse Power fuse for insertion into power fuse holder for protection of 12 V and 24 V installations. Power Strengths and Order No. see table below
|
||||||||||||||||||||||
18 | 2242 | Fuse Holder for Strip Fuses Fuse holder for strip fuse for protection of larger consumers. Both sides of the fuse holder are equipped with a thread M5. Delivery excluding fuse. Dimensions: 70 x 42 x 22 mm |
||||||||||||||||||||||
19 | see Table |
Strip Fuse, packaging quantity 3 pieces Strip fuse for insertion into fuse holder (fig. 18), as well as for Plus Distributor 8 for protection of 12 V and 24 V installations. Power Strengths and Order No. see table below
|
||||||||||||||||||||||
20 | 2213 | Cable fuse holder IP 56 for automotive flat fuses Fully insulated fuse holder (IP 56) for automotive flat fuses. Strand 2.5 mm², red, length of both sides approx. 235 mm. Delivery excluding fuse. Dimensions: 39 x 14 x 27 mm |
||||||||||||||||||||||
- | 2262 2263 |
High-Current Cable 25 mm², Length: 40 cm High-Current Cable 35 mm², Length: 40 cm High-current cable, orange, highly flexible, both sides are equipped with cable lugs for bolts M8, for connection of power fuse holder and battery. Other lengths can be manufactured on request. |
||||||||||||||||||||||
21 | 2268 2269 2272 2273 |
Connection Cable for SMI Inverter Red/Black 25 mm², Length: 1 m Connection Cable for SMI Inverter Red/Black 35 mm², Length: 1 m Connection Cable for SMI Inverter Red/Black 25 mm², Length: 2 m Connection Cable for SMI Inverter Red/Black 35 mm², Length: 2 m Cable sets for plus (red) and minus (black) battery connection of the SMI Inverters “ST”, highly flexible high-current cables, ready-made, including pipe cable lug for bolt M8, Art.-No. 2268 & 2272: 25 mm² for SMI 1200 ST(-NVS) Art.-No. 2269 & 2273: 35 mm² for SMI 1700 ST(-NVS) |
||||||||||||||||||||||
22 | 2065 | Control Unit On/off control unit for VOTRONIC Sine Inverter SMI (-NVS) of all capacity classes. The control is effected by a +12 V signal (ON), e. g. of D+ (inverter works automatically during motor operation for light pole, air-conditioner, refrigerating and heat boxes, large consumers etc.) or centrally from a general main switch (all units including the power packs are switched-on/off when entering or leaving the vehicle). Delivery Scope: Control Unit, Connection Cable 30 cm length, Operating Manual |
||||||||||||||||||||||
23 | 2067 | Additional Remote Control for Sine Inverter Extension set with 2nd remote control for VOTRONIC Sine Inverter SMI (-NVS) of all capacity classes. In addition to the remote control, which is included in the standard delivery of the inverter, it allows complete control and further operation of the inverter from a second location (right / left, driver’s cabin / body). Delivery Scope: Remote Control, Y distributor, connection cable 5 m, connection cable 30 cm length |
||||||||||||||||||||||
24 | 2007 | Cable Set for Connection Solar Charging Controller at EBL Readily assembled Cable Set for the connection of a VOTRONIC Solar Charging Controller at the suitable output of an existing Schaudt "Elektroblock (EBL)" with connected Controll and Display Panel (DT.../LT...). Please check in advance the compatibility of your Schaudt Electrobloc (EBL) and the corresponding control panel, because we are not able to give any warrenty for this. Delivery Scope: Cable Set 1 m length, Operating Manual |
||||||||||||||||||||||
25 | 2023 | Cover for Smart Shunt Plastic cover for Smart-Shunt 100, 200 and 400 for LCD-Batterie Computer S or VPC Jupiter. |